Herunterladen Inhalt Inhalt Diese Seite drucken

Maintenance And Servicing Plan; Table Of Measures; Changing The Exciter Oil; Exciter Oil Change Zi-Rpe60C - Zipper Zi-Rpe60C Betriebsanleitung

Vorschau ausblenden Andere Handbücher für ZI-RPE60C:
Inhaltsverzeichnis
Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 18
17.1

Maintenance and Servicing PLan

17.1.1

Table of Measures

What to do?
Check fuel level
Check engine oil level
Control of the operating elements
Check for damaged parts
Checking for loose or lost screws
Change engine oil
Check V-belt
Change exciter oil
Air filter cleaning
Spark plug test
The specified intervals refer to working under "normal" operating conditions. Depending on the
load, a change/exchange may also be necessary at an earlier point in time.
17.2

Changing the exciter oil

17.2.1

Exciter oil change ZI-RPE60C

17.2.2 Exciter oil change ZI-RPE90C

To drain the exciter oil, remove the drain screw (B) on the exciter (A). Then tilt the machine. Fix the
drain screw (B) again and fill up fresh oil (screw (C)). Recommended oil is ISO VG68 or similar about
350ml is needed for a refill.
17.3

Changing the engine oil

ZIPPER MASCHINEN GmbH
www.Zipper-Maschinen.at
Waste oils are toxic and must not be released into the environment!
Contact your local authorities for information on proper disposal.
To drain the exciter oil, remove the drain screw (B) from the exciter (A) and
then tilt the machine. (Note that the oil can drain more easily when warm.)
Then straighten the machine again and top up with fresh oil. Recom-
mended oil is ISO VG68 or similar about 250ml is needed for a refill.
Waste oils are toxic and must not be released into the environment!
Contact your local authorities for information on proper disposal.
1.
Remove the oil drain hose (A) from the holder (B).
2.
Remove the screw on the oil drain hose. Collect the drained oil in
a collecting container and dispose of it properly!
3.
Tighten oil drain plug again after emptying.
4.
Top up with fresh oil via the filling opening (K) (see section
Checking the engine oil level).
Only use high-quality engine oil, e.g. 15W40 or similar!
Frequency
before each start-up
before each start-up
before each start-up
before each start-up
before each start-up
first after 20 h, then every 100 h
every 50 h; replacement after 300 h or 1 year
every 200 h
every 50 h, replacement after 300 h or 1 year
every 100 h; replacement after 300 h or 1 year
N O T E
N O T E
MAINTENANCE
37
ZI-RPE60C | ZI-RPE90C
Inhaltsverzeichnis
loading

Diese Anleitung auch für:

Zi-rpe90c

Inhaltsverzeichnis