Connector X6:
Pin
Type of signal
1
digital Input
2
digital Input
3
analog Input
4
digital Input
5
digital Input
6
digital Input
7
-
8
digital Output
9
-
10
digital Output
11
analog Input
Connector X7:
Pin
Type of signal
1
-
2
-
3
analog Output
4
digital Input
5
digital Input
6
digital Input
7
digital Input
8
digital Input
9
-
10
-
11
analog Output
12
digital Input
13
digital Input
14
digital Input
15
digital Input
16
digital Input
Signal
Supply Voltage +24 V
Welding simulation
For the MIG/MAG welding process:
Pulse-/dynamic correction command value
For the TIG welding process:
vD correction
GND for digital Inputs
Torch blow out
Wire backward
-
Supply Voltage +24 V
-
Limit signal = factory assignment
Torch body gripped = on the website of the welding
machine, the pin can also be assigned this signal if
desired
GND for X6/3
Signal
-
-
For the MIG/MAG welding process:
Actual real value for seam tracking
For the TIG welding process:
Actual real value AVC
Working mode, Bit 3
Working mode, Bit 4
Welding characteristic- / Job number, Bit 8
Welding characteristic- / Job number, Bit 9
Welding characteristic- / Job number, Bit 10
-
-
GND for X7/3
Welding characteristic- / Job number, Bit 11
Welding characteristic- / Job number, Bit 12
Welding characteristic- / Job number, Bit 13
Welding characteristic- / Job number, Bit 14
Welding characteristic- / Job number, Bit 15
Englisch (US)