Herunterladen Inhalt Inhalt Diese Seite drucken

Clean The Grease Separator - Kessel SE NS 2 Bedienungsanleitung

Fettabscheider zur selbstentsorgung mit manueller entsorgungseinrichtung
Inhaltsverzeichnis

Werbung

Permanent odour development
Fault
Possible cause
Odour pollution
Wastewater pipes leaking.
No venting pipe, cross-section too
small.
Barrel cover, screw clamp, filling nozzle
not airtight.
Hoses
Full barrels have been stored too long,
contents are fermenting.
Lifting stations
Closed room with no air exchange.
7.3

Clean the grease separator

Tätigkeiten durchführen, die unter
on chamber).
Make sure that no more wastewater can be fed into it.
Move the main switch to the OFF position (variants with two heating mantles have two control units, both must
be switched off).
Screw the cover off the access opening <83> and rinse thoroughly with hot water.
Remove the inspection cover <23> (only NS 15-25).
Revisionsdeckel Balance-Tower <30> abmontieren.
Anlage entleeren, dazu aus dem Balance-Tower <31> das Abwasser absaugen, oder über den Absperrschieber
entwässern.
Take the ventilation for the heating mantle(s) <36> off.
2017/10
Maintenance
4.3 on page 58 Disposal (emptying the sludge trap and grease collecti-
➲ 
36
83
23
Ill. [17]
Action
Check firm fit and seals, repair if necessary.
Retrofit on-site.
Check firm fit and seals, repair if necessary.
Check hose clamps, tighten if necessary.
Have barrels taken away more often.
Not (sufficiently) ventilated.
Create ventilation possibilities, forced ventilation.