3.3
Delivery Specification
Designation
Splash guard housing
Assembly panel with high-pressure rail
CRE 800 actuating unit
Connection set (assem-
bly parts for pump inlet)
Pressure control valve for overflow
Connecting cable
Magnetic cores (x 4)
Serial connecting cable (8 m)
Adapter cables with compact connector 1.1 (x 3) 1 684 460 255
Adapter cables with blade receptacles (x 3)
Filter (2 x; spare part)
Shut-off valve
Connecting line
(pressure reducer control)
CD EP-Software
CD TestData
CRS 845H modification instructions
CRS 845H operating instructions
Program description for EP software
Safety information
Modification instructions for magnetic cores
3.4
Special Equipment
Designation
Heat exchanger
Parts kit with
High-pressure hose 250 MPa
Test pressure line 90°
Adapter nut M12 x 1.5
Adapter nut M14 x 1.5
Adapter nut M16 x 1.5
Supplementary-equipment set
(12 cooling channels)
Supplementary-equipment set (rising pipe)
Supplementary-equipment set CP1
Supplementary-equipment set CP2
Supplementary-equipment set CP3.x
Accessory set for CP3.4 (MAN)
Parts kit for delivery pressu-
re measurement for CP3
Accessory set for other manufactur-
ers (Delphi, Denso and Siemens)
Test set CRI 846H for Common Rail injectors
Adapter with pressure limiter
For connecting the high-pressure hose to
the CRI 846 distributor rail (180 MPa).
Robert Bosch GmbH
Product Specification | CRS 845H | 25
3.5
Order number
1 685 510 227
1 687 240 930
1 687 023 560
1 687 001 547
1 687 417 087
1 684 462 511
1 680 300 236
1 684 465 388
1 684 460 256
1 687 012 144
1 687 415 058
1 684 463 745
1 687 000 956
1 687 370 270
1 689 978 535
1 689 989 069
1 689 989 099
Fig. 1:
1 689 979 860
1 Control device
1 689 978 430
2 KMA 802
3 Assembly panel
4 Pressure control valve
5 Splash guard housing
Order number
3.6
1 687 010 336
While testing common-rail high-pressure pumps, test
1 687 016 064
pressures of up to 220 MPa (2200 bar) can be generated
in the test system. In order to protect the user against
the constant presence of test pressures, the installation
of a splash guard with inductive proximity switch safety
monitoring is necessary.
1 687 001 557
1 687 001 544
1 687 010 341
1 687 010 342
1 687 010 182
1 687 001 619
1 687 010 151
1 687 010 183
1 687 002 846
1 681 032 094
General Overview
5
General Overview
Splash guard housing
Danger of test oil escaping under high
pressure and high temperatures!
Danger of damage to skin and eyes!
¶
Only test with the safety device closed.
¶
Never switch off the safety device.
1 689 989 069
en
1
2
3
4
|
2012-03-01