All work that has not been listed in these Instruc-
tions must only be carried out by authorised servic-
ing agencies.
• Treat the implement with the greatest care. Always
keep the tool clean for better and safer work. Follow
the maintenance instructions.
• Never overload the implement. Always work within
the specified capacity range. Do not use low-power
machines for heavy-duty work. Do not operate the
implement for purposes for which it is not intended.
Electrical safety:
Caution! The following states how to avoid accidents
and injuries due to electric shock:
• Before each use, carry out a visual inspection of the
power and extension cables for signs of damage or
ageing.
• If the power cable for this equipment is damaged,
it must be replaced by the manufacturer, a custom-
er service agent of the same or a similarly qualified
person in order to prevent hazards.
• Keep the power cable well away from the cutting
tools. Should the power cable become damaged
during work, then instantly disconnect the power ca-
ble from the mains.
Do not touch the power cable before it has been
disconnected from the mains.
• Keep the extension cables away from the teeth. The
teeth may damage the cables and result in contact
with live parts.
• Check that the mains voltage is the same as indicat-
ed on the rating plate.
• Wherever possible connect the implement to a pow-
er socket with a residual- current circuit breaker that
has a rated current of not more than 30 mA.
• Avoid body contact with earthed parts (e.g. metal
fences, metal posts).
• Only use approved extension cables of the type
H05VV-F or H05RN-F with a maximum length of 75
m and which have been approved for open-air use.
The stranded cord diameter of the extension cable
must be at least 2.5 mm2. Always unreel a cable
drum to its full length so that the entire cable can be
checked for damage.
• Use the envisaged cable suspension when attach-
ing an extension cable.
• Never pull the cable to disconnect the plug from the
socket. Protect the cable from heat, oil and sharp
edges.
• If the connecting cable is damaged, first dis-
connect the extension cable from the socket.
24 | GB
You can then disconnect the connecting cable of the
equipment.
• If the power cable for this equipment is damaged,
it must be replaced by the manufacturer, a custom-
er service agent of the same or a similarly qualified
person in order to prevent hazards.
Residual risks
Even if you use this electric power tool in accord-
ance with instructions, certain residual risks can-
not be rules out. The following hazards may arise
in connection with the equipment's construction
and layout:
1.
Damage to hearing if no suitable ear protection is
used.
2.
Health damage caused by hand-arm vibrations if
the equipment is used over a prolonged period or
is not properly guided and maintained.
Warning! This electric tool generates an electromag-
netic field during operation. This field can impair active
or passive medical implants under certain conditions.
In order to prevent the risk of serious or deadly injuries,
we recommend that persons with medical implants
consult with their physician and the manufacturer of
the medical implant prior to operating the electric tool.
5. Technical data
Main Voltage
Power Input
Working width
Number of blades
Number of claws
Scarifing depth
Protection class
Protection type
Weight
Information about noise level measured in accord-
ance with applicable standards:
Sound pressure L
Sound power L
Uncertainty K
www.scheppach.com
230-240V~ 50Hz
pA
WA
/ K
PA
WA
1500W
320 mm
16
20
-12 / +4 mm
II
IPX4
8,5 kg
84,5 dB
97,3 dB
3 dB