Subject to technical changes!
Operating mode S1 (continuous operation)
The product can be operated continuously with the speci-
fied power.
Operating mode S2 (short-term operation)
The product may only be operated at the specified power
for a brief time (5 min.).
WARNING
Noise can have serious effects on your health. If the
machine noise exceeds 85 dB, please wear suitable
hearing protection for you and persons in the vicinity.
Information about the noise level measured in accordance
with applicable standards (EN ISO 3744:1995, ISO
8528-10:1998):
Sound pressure L
pA
Sound power L
wA
Measurement
uncertainty
K
pA
7
Unpacking
• Open the packaging and carefully remove the product.
• Remove the packaging material, as well as the pack-
aging and transport safety devices (if present).
• Check whether the scope of delivery is complete.
• Check the product and accessory parts for transport
damage. Immediately report any damage to the trans-
port company that delivered the Product. Later claims
will not be recognised.
• If possible, keep the packaging until the expiry of the
warranty period.
• Familiarise yourself with the product by means of the
operating manual before using for the first time.
• With accessories as well as wearing parts and re-
placement parts use only original parts. Spare parts
can be obtained from your specialist dealer.
• When ordering please provide our article number as
well as type and year of manufacture for the product.
WARNING
The product and the packaging material are not
children's toys!
Do not let children play with plastic bags, films or
small parts! There is a danger of choking or suffo-
cating!
8
Before commissioning
Electrical safety
Prior to use, the power generator and its electrical equip-
ment (including lines and plug connectors) should be
checked to ensure that there are no defects.
Never connect the power generator to the mains (socket).
The power lines to the consumer must be kept as short as
possible.
24 | GB
WARNING
Health hazard!
Inhalation of fuel / lubricating oil vapours and exhaust
gases can cause serious damage to health, uncon-
sciousness and in extreme cases death.
–
Do not breathe fuel / lubricating oil vapours and ex-
haust gases.
–
Operate the product outdoors only.
ATTENTION
Product damage!
Using the product without or with too little engine and
gear oil can result in engine damage.
–
Fill with fuel and oil before commissioning. The
product is supplied without engine and gearbox oil.
71.6 dB
91.6 dB
ATTENTION
1.13 dB
Environmental damage!
Spilled oil can pollute the environment permanently.
The liquid is highly toxic and can quickly lead to water
pollution.
–
Fill/empty oil only on level, paved surfaces.
–
Use a filling nozzle or funnel.
–
Collect drained oil in a suitable container.
–
Wipe up spilled oil carefully immediately and dis-
pose of the cloth according to local regulations.
–
Dispose of oil as per local regulations.
Check before operation
• Check all sides of the engine for oil or fuel leaks.
• Check the engine oil level.
• Check the fuel level – the fuel tank should be at least
half-full.
• Check the condition of the air filter.
• Check the condition of the fuel lines.
• Look for signs of damage.
• Check that all protective covers are in place and all
screws, nuts and bolts are tightened.
• Ensure that the product is sufficiently ventilated.
• Make sure that the spark plug connector is attached to
the spark plug.
• Remove any consumer that may be connected.
8.1
Earthing screw (12) (Fig. 3)
ATTENTION
Electric shock!
–
Do not use bare wires for earthing.
–
Product must be safely earthed.
Earthing the housing is necessary to discharge static
charging. To do this, connect a cable on one side to the
earthing screw (12) of the power generator and on the
other side to an external earth (e.g. earth rod).
www.scheppach.com