7.2.
GENERAL CHARACTERISTICS
Power supply
Battery type:
Mechanical characteristics
Dimensions (L x W x H):
Weight (battery included):
Mechanical protection:
Reference guidelines
Instrument safety:
EMC:
Insulation:
Overvoltage category:
Max height:
Pollution level:
7.3.
ENVIRONMENT
7.3.1. Environmental conditions for use
Calibration reference temperature:
Operating temperature:
Allowable relative humidity:
Storage temperature:
This instrument satisfies the requirements of Low Voltage Directive 2014/35/EU
This instrument satisfies the requirements of European Directive 2011/65/EU (RoHS)
7.4.
ACCESSORIES
7.4.1. Standard accessories
• Mobile lead L1 (Code: PR9)
• Protective cap for test leads, 2 pcs
• Adapter for 4mm test lead tip, 2 pcs
• Batteries (not inserted)
• User manual
2x1.5V alkaline type AAA, IEC LR03
255 x 60 x 35mm (10 x 2 x 1in)
approx. 170g (6 ounces)
IP64
IEC/EN61010-1 (HT8, HT9);
IEC/EN61010-2-030 (HT8, HT9);
IEC/EN61243-3:2014 (HT6, HT8, HT9)
IEC/EN61326-1
double insulation
CAT III 690V; CAT IV 600V
2000m (6562ft)
2
23°C ± 5°C (73°F ± 41°F)
-15°C ÷ 55°C (5°F ÷ 131°F)
<95%RH
-20°C ÷ 70°C (-4°F ÷ 158°F)
(LVD) and of EMC Directive 2014/30/EU
and 2012/19/EU (WEEE)
EN - 14
HT6 - HT8 - HT9