7. TECHNICAL SPECIFICATIONS
7.1.
TECHNICAL CHARACTERISTICS
Voltage measurement with LED indication
Voltage range:
Rated voltages:
Accuracy:
ELV indications:
Response time:
Working time:
Consumption during measurement:
Voltage measurement with display indication
Accuracy indicated as [%reading + (number of digits)] at 23°C±5°C, <70%HR
AC/DC voltage
Range [V]
Resolution [V]
10.0 690.0
Max input current: <3.5mA (at 690V);
Frequency range: 16 - 400Hz;
Phase detection function
Voltage range:
Frequency:
Phase sequence
Voltage range:
Frequency range:
Measuring mode:
Continuity test
Detection range:
Lamp test
Voltage with new battery:
Range intensity 200-280 kHz:
Indications:
Charging time before test:
Flashing frequency:
Test time:
Working time:
Consumption during test:
12690V DC/AC (16400Hz)
12/24/50/120/230/400/690V DC/AC (16400Hz)
compliance with IEC/EN61243-3:2014
>50VAC, >50VDC
< 1s at 100% of any rated voltage
after 30s of continuous measurement, the
instrument must make a pause of 240s before
starting a new measurement.
approx. 50mA (battery 3V, measuring 690V AC)
(HT6, HT8)
Precision
(3rdg+5digits)
0.1
Automatic AC/DC voltage detection;
"OL": Over Range indication
100 690V
50 / 60Hz
120400V Phase-Earth
50/60Hz
2 terminals on non-isolated parts
0500k + 50%
approx. 3kV / 240kHz
approx. 100µV/m
"Test" LED on
<0.5s
2Hz
typically <2s
may operate in continuous mode
approx. 500mA
EN - 13
HT6 - HT8 - HT9
Input
Max voltage
impedance
690VAC/DC
200K