5.4.
CONTINUITY TEST AND DIODE TEST
Before carrying out any continuity test, check that the resistance to be
measured is not live. Failure to respect this prescription may seriously harm
the operator.
Fig. 6: Continuity test
CAUTION
Continuity test
1. Connect the measuring leads L1 and L2 to the object
to be tested (see Fig. 6)
2. The instrument switches on automatically together with
LED RX (see Fig. 2 – Part 6) and the buzzer
continuously in case the result of the continuity test is
positive
3. The continuity test is active
tested is
<500k
Diode test
This test is OK for standard rectifying,
signaling, Schottky diodes, but not working
for LED diodes
1. Touch with the tip L2 (see Fig. : 1 - Part 2) the cathode
and with the tip L1 (see Fig. : 1 - Part 3) the anode →
Rx LED is on and the buzzer beeps
2. Touch with the tip L1 the cathode and with the tip L2
the anode → Rx LED is off and the buzzer does not
beep
3. In case of measurements in environments with poor
light, press the Torch button (see Fig. : 1 – Part 7) to
activate the white LED pointer.
EN - 10