- Power supply with protection against short-circuits and oveload on
"FLASH", "LED" and "IND/ELEC" outputs.
- Obstacle detection.
- Automatic learning of stroke.
TECHNICAL SPECIFICATIONS
Power supply of control board
Max motor load
Max current for "24VAC" output
Max current for "PHPOW" output
Max power for "FLASH" output
Max power for "LED" output
Max power for "IND / ELEC" output
Fuse of control unit
Max. number of trasmitters storage
Operating temperature
2.4 - List of cables required
The cables required for connection of the various devices in a stan-
dard system are listed in the cables list table.
The cables used must be suitable for the type of installation; for
ELECTRIC CABLE TECHNICAL SPECIFICATIONS
Connection
Flashing light, courtesy light
Antenna
Electric lock
Transmitter photocells
Receiver photocells
Sensitive edge
Key-switch
3 - PRELIMINARY CHECKS
Before installing the product, perform the following checks and in-
spections:
- check that the gate, the door or the barrier is suitable for automa-
tion;
- the weight and size of the gate or door and the balance of the
barrier boom must be within the operating limits specified for the
automation system in which the product is installed;
- heck that the gate or door has firm, effective mechanical safety
stops;
- make sure that the product fixing zone is not subject to flooding;
- high acidity or salinity or nearby heat sources might cause the pro-
duct to malfunction;
- in case of extreme weather conditions (e.g. snow, ice, wide tempe-
rature variations or high temperatures), friction may increase, cau-
sing a corresponding rise in the force needed to operate the sy-
stem;
- the starting torque may therefore exceed that required in normal
conditions;
- Safety device deactivation by means of dip switches: there is no
need to bridge the terminals of safety devices which are not in-
stalled. The function is simply disabled by means of a dip switch.
24 Vac ± 10% - 50/60 Hz
200 mA (24 Vdc unregulated)
5 W (24 Vdc) / 15 VA (12 Vdc)
example, an H03VV-F type cable is recommended for indoor appli-
cations, while H07RN-F is suitable for outdoor applications.
cable
3 x 0,5 mm
2
1 x cable type RG58
1 x cable 2 x 1 mm
2
1 x cable 2 x 0,5 mm
2
1 x cable 4 x 0,5 mm
2
1 x cable 2 x 0,5 mm
2
1 x cable 4 x 0,5 mm
**
2
- check that when operated by hand the gate, the door or the barrier
moves smoothly without any areas of greater friction or derail-
ment risk;
- check that the gate, door or the barrier is well balanced and will
therefore remain stationery when released in any position;
- check that the electricity supply line to which the product is to be
connected is suitably earthed and protected by an overload and
differential safety breaker device;
- the system power supply line must include a circuit breaker device
with a contact gap allowing complete disconnection in the condi-
tions specified by class III overvoltage;
- ensure that all the material used for installation complies with the
relevant regulatory standards.
CT10324
200 W
200 mA (24 Vac)
15 W (24 Vdc)
15 W (24 Vdc)
1.6 AT (time lag)
150
-20°C +55°C
maximum allowable limit
20 m
20 m (advised < 5 m)
10 m
20 m
20 m
20 m
20 m
EN
21