ELECTRONIC BOARD SETTINGS
OBSTACLE
DETECTION
OVL
'-' more sensitive
'+' less sensitive
Trimmer VR 2 (PAU) serves two purposes: the first being to adjust the pause time before automatic closing,
and the second (when turned all the way to '+') to set the unit to jog mode.
Note:
by the card.
Important:
The fitter at the end of the installation must check that the motor conforms to paragraph 5.1.1.5 of the EN
12453 standard (limitation of forces article 5.2.1 of the EN 12453 standard).
Starting of the leaves: The force must be sufficient and not excessive to open and stop the gate, without re-
bound and without distortion, you should, if necessary, adjust the setting VR1 – (FOR), this setting controls the
speed of the leaves, and must be adapted to the type of the gate used (heavy, light, full or open-work....).
Stop on obstacle: To avoid any risk of injury, the force at the end of the leaf shall not exceed 15 kg of driving
force whatever the conditions of use. If necessary, consult a qualified fitter.
If necessary, you have to adjust the setting VR5 (OVL) according to the type of gate used (For safety reasons,
you must be able to stop the course of the gate by hand).
Reminder: The person who installed the automated system is responsible for the installation.
REACION TIME TO
SHIFT
THE OBSTACLE
DEL
'-' min. motor shift at
'-' lower reaction
closing
time
'+' max. motor shif at
'+' higher reaction
closing
time
(3 to 20 sec.)
(0,1 to 3 sec.)
-
0
45 sec.
PAUSE TIME
OBS
'+' maximum jog
'-' pause time in
automatic mode
(3 to 90 sec.)
+
90 sec.
jog mode
19GB
WEAT V2 N - V1
FORCE
PAU
FOR
'-' lower motor force
'+' stronger motor force

Werbung