Herunterladen Diese Seite drucken

Extel WEAT V2 N Installations- Und Bedienungsanleitung Seite 148

Torantriebsset für flügeltore

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 158
QUICK START-UP
Connect the unit, the worm screws, the photocells, the beacon and the power supply. Leave the leaves half
open.
During quick start, it is imperative to position the trimmer VR3 (OBS) at the minimum so that slowing downs
are taken into account, and if necessary help manually the leaves or increase VR5 (OVL).
Energise the unit and press
the RESET button
for 2 sec.
(before 5 sec.)
Press the P1/SET button
Until the motors start
End of auto-memorisation
procedure
Reset to VR3 (OBS) adjustment in order the gate does not stop inopportunely in case of wind.
P1/SET
LD1
Green LD1 flashing
Green LD1
lit steadily
Motors stopped
The leaves open
to the stops
Green LD1 off
17GB
WEAT V2 N - V1
RESET
Safety mechanisms and
motor registered
Leaves open for
4 seconds then close
Motors stopped after 3
seconds
Leaves close one after
the other
Motors stopped