4. Installation
A
B
~2 Nm
~ 3 Nm
24
13
• In addition, a distance of min. 5 cm must be maintained on at least two sides of the
unit.
• When using metallic covers in front of the appliance, a distance of min. 1 cm to the
control panel must be maintained.
Mounting the appliance
1. Thoroughly rinse the water supply pipes before installation to remove soiling from
the pipes.
2. Hold the appliance on the wall, and mark the drill lines at top and bottom, right and
left, corresponding to the small notches at the edge of the appliance hoo.
B
Important: If the water connection pipes are already firmly installed in their position,
the sealing surface of the appliance connections must reach the sealing surface of the
connection pipes so that the markings are at the correct height.
3. Connect the top and bottom marks vertically with each other (A–A).
B
4. Connect the right and left marks horizontally with each other (B–B).
5. The intersections of these lines are the drill points.
6. Drill the holes using a 6 mm drill. Insert the included dowels and screws. The screws
have to protrude 20 mm.
7. Hook the appliance into the suspension openings and press down gently.
8. Then tighten all screws with approx. 2 Nm to secure the appliance against slipping.
4 ×
Connecting the water pipes
• Screw the cold water pipe with union nut and the ½ inch gasket to the cold water
connection of the appliance.
• Screw the hot water pipe with union nut and the ½ inch seal to the hot water con-
nection of the appliance.
• Turn valve »a« to position »1«.
a
0
Ø 6 mm
Ø 6 mm
1
a
61