Herunterladen Diese Seite drucken

clage ISX Gebrauchs- Und Montageanleitung Seite 53

E-komfortdurchlauferhitzer
Vorschau ausblenden Andere Handbücher für ISX:

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 1
5. CLAGE app "Smart Control"
Value Description
Operation without load shedding
0
relay, factory setting
Operation with normal
1
load shedding relay
Operation with sensitive
2
load shedding relay
Load Shedding: If further three-phase appliances are connected, a load shedding relay
designed for electronic instantaneous water heaters (CLAGE no. 82250) can be con-
nected to phase conductor L2. This relay ensures the operation of the water heater by
switching off other consumers until the end of heating operation.
Tap on
or
and hold for two seconds to set a value of 0, 1 or 2.
Operating mode 1 must be selected first, thus to check the correct operation of the
load shedding relay at low appliance output (35 degree celsius setpoint and low water
flow rate). Mode 2 must be selected if the load shedding relay flickers.
Factory Settings: All factory settings can be recalled:
• Restart Device: Set the temperature back to factory setting and restart the appli-
ance.
• Factory Reset: Deletes all entries made by the user inclusive statistics.
• Reset User Settings: Deletes all user profiles.
Note: To access all reset functions, the app must be connected to the appliance via
WLAN.
Devices: Here you will find all the parameters for connecting the ISX with WLAN,
Bluetooth or Modbus. For more information, see page 47.
53
CLAGE
EN

Werbung

loading