Herunterladen Diese Seite drucken

clage ISX Gebrauchs- Und Montageanleitung Seite 44

E-komfortdurchlauferhitzer
Vorschau ausblenden Andere Handbücher für ISX:

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 1
ISX
4. Remote control
EN
Value Description
Operation without load shedding
0
relay, factory setting
Operation with normal
1
load shedding relay
Operation with sensitive
2
load shedding relay
If both entries match, you can access the section "Protected Sections".
Protected Sections: Select the areas for a PIN lock.
• Lock Settings: Automatically active as soon as a password has been generated.
Users can only access the settings menu with a PIN. Deactivating it deletes the cur-
rent PIN.
• + Lock Main Menu: Users can only access the main menu with a PIN
• + Lock Temperature: The outlet temperature is set to the current value and can only
be changed with a PIN. User profiles and applications can also only be changed with
a PIN.
Electricity price (currency/kWh): Specify the electricity price of your own electricity
supplier.
Water price (currency/m³): Specify the water price of your own water supplier.
Load Shedding: If further three-phase appliances are connected, a load shedding relay
designed for electronic instantaneous water heaters (CLAGE no. 82250) can be con-
nected to phase conductor L2. This relay ensures the operation of the water heater by
switching off other consumers until the end of heating operation.
Select "OK« to activate the edit mode. To set a value of "0", "1" or "2" press and hold
 or 
for two seconds.
Operating mode 1 must be selected first, thus to check the correct operation of the
load shedding relay at low appliance output (35 degree celsius setpoint and low water
flow rate). Mode 2 must be selected if the load shedding relay flickers.
Factory Settings: All factory settings can be recalled. Temperature limit for showering
and load shedding are not affected.
Note: All customised user profiles and power and water prices entered, are deleted.
Delete Statistics: Use this function to delete all previously collected statistical data.
Deleted statistical data cannot be restored.
Usage profile: You can choose between a profile for kitchen and bathroom. Each pro-
file has its own application icons and different predefined temperatures.
Thermal treatment: With this function, you can support a thermal treatment of your
appliance and the following pipeline, including the tap. A thermal disinfection accord-
ing to the accepted rules of technology is not replaced.
• Tap "OK« to start the treatment cycle and the outlet temperature is set to 70 °C.
The function is disabled if the appliance is connected to a shower.
• Draw hot water for at least three minutes to heat the pipes to the tap completely.
• A change of the temperature or 30 sec without water flow terminates the treat-
ment cycle.
• The number as well as the accumulated duration and the water amount of all ther-
mal treatments will be saved.
Notes:
Ensure that no one can be injured by the elevated temperatures and that the installa-
tion can withstand the strain.
The exiting water and the tap become very hot! The water steam should not be
inhaled.
Disconnect appliance: Deregisters the remote control from your appliance.
44

Werbung

loading