ISX
3. Dimensions
EN
4. Installation
278
278,2
The following regulations must be observed:
• e.g. VDE 0100
• EN 806
• Installation must comply with all statutory regulations, as well as those of the local
electricity and water supply companies.
• The rating plate and technical specifications
• Only intact and appropriate tools must be used
Installation site
• Appliance must only be installed in frost-free rooms. Never expose appliance to
frost.
• The appliance is designed for wall mounting and must be installed vertically with
water connections at the bottom.
• Alternatively, the appliance can be installed horizontally with water connections on
the left or hanging flat from the ceiling.
• The unit complies with protection class IP21 and may only be installed in protection
area 3 according to VDE 0100 part 701 (IEC 60364-7).
• In order to avoid thermal losses, the distance between the instantaneous water
heater and the tap connection should be as small as possible.
• The appliance must be accessible for maintenance work.
• Plastic pipes may only be used if they conform to DIN 16893, Series 2.
• The specific resistance of the water must be at least 1100 Ω cm at 15 °C. The specific
resistance can be asked for with your water distribution company.
• Do not install the device in the immediate proximity of metal surfaces to allow a
reliable wireless connection and an optimal wireless range.
• When mounted vertically or horizontally in a built-in cabinet, this must have a vol-
ume of at least 50 litres for ventilation purposes.
• If the appliance is installed overhead or in a false ceiling, there must be an area with
a volume of at least 300 litres for ventilation (e.g. 1 m × 1 m ×0.3 m).
Dimensions in mm
170
170
38
37,5
60