1-6-12. Cylinder Holding Plate Replacement
1. Remove screws (1) and (2) securing the cylinder
holding plate (3) and a screw (5) securing the cylinder
holding plate (4).
2. Remove the cylinder holding plate (3) and (4) sliding
in the direction shown by the arrow (B) and (A).
3. Eliminate the cylinder lock key (wedge shaped parts).
4. After replacing the cylinder holding plates (3) and (4),
mount new parts in the reverse order of removal.
Note:
* When remounting, fix the cylinder while pushing in
the direction shown by the arrow (A) and the cylinder
holding plate (3) in the direction shown by the arrow
(B). Then tighten three screws while pushing the
cylinder holding plate (4) toward the stopper on the
outsert of the mechanical deck.
* Tightening order of the screws is (1) > (2) > (5).
¢ Tightening torque of the screws (1), (2), (5) is 294 —
392 mNem (3 — 4 kgecm).
Head
cleaner
D A
S "
|_Screw (1)
ef (2)
Screw (5)
Cylinder holding
plate (3)
Cylinder holding
plate (4)
Cylinder
lock key
1-6-14. Head Cleaner Replacement
<Roller sub assembly replacement>
1. Remove the roller sub cleaner assembly (2) pulling
upward from the hook (A) on the cleaner lever (1).
2. After replacing the roller sub assembly, mount in the
reverse order of removal.
<Cleaner lever replacement>
1. Undo the hook (B) of the cleaner lever (1) from the
mechanical deck, and pull out the cleaner lever (1)
upward.
2. Replace the cleaner lever (1) on the roller sub assem-
bly (2), and mount the cleaner lever (1) in the reverse
order of removal.
Note:
* Take care the roller sub assembly (2) is not stained
with grease or oil.
Stopper rib (C)
Roller sub assembly (2)
Hook (A)
Cleaner lever (1)
Hook (B)
Joint portion of
elastic spring
Mechanical
lec!
Stopper (D)
Assist pin
Fig. 6-14-1
Note:
*
When remounting the head cleaner, position the
stopper rib (C) in front of the stopper (D)-
Cleaner lever (1)
Stopper rib (C)
\
Fig. 6-14-2
Stopper (D)