1.9.4
Separation guard
Adjust the guard (1) to the correct height
before you start working.
To do so, slacken the clamping screw, set
the required height and re-tighten the
clamping screw.
There is a switch integrated in the spindle
protection mounting which monitors the
closed position.
INFORMATION
The machine cannot be started, if the spin-
dle protection is not closed.
1.10
Safety check
Check the milling machine regularly.
Check all safety devices
before starting work,
once a week (with the machine in operation) and
after all maintenance and repair work.
General check
Equipment
Guards
Signs,
Markers
Functional check
Equipment
Emergency stop button
Separation guard around
the drill and milling spindle
Version 1.0.5 - 2021-01-29
Img.1-3:
Separation guard
Check
Mounted, firmly bolted and not damaged
Installed and legible
Check
After the emergency stop button is pressed, the milling machine
must switch off. It must only be possible to restart the machine, if
the emergency stop button is unlocked and the ON switch has
been pressed.
The milling machine may switch on only when the guard is
closed.
Translation of original instruction
1
OK
OK
MH50G│MH50V