Herunterladen Diese Seite drucken

Optimum 3338180 Betriebsanleitung Seite 64

Vorschau ausblenden Andere Handbücher für 3338180:

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

Overview of the EMC categories:
Categorie C1
required limit values Class B Group 1 according to EN 55011
Categorie C2
Required limit values class A Group 1 according to EN 55011, Installation by EMC experts
and warning: "This is a product of category C2 according to EN 61800-3. This product may
cause radio interference in a residential area. In this case, it may be necessary for the ope-
rator to take appropriate action."
Categorie C3
Required limit values class A group 2 according to EN 55011, whereby these limit values
are below those of class A group 1, plus warning: „This type is not suitable for connection to
a public low-voltage network supplying residential buildings. When connecting to a public
low voltage network, radio frequency interference is expected. "
MH50V
Categorie
Environment
Voltage / Current
EMC knowledge
1.5
Possible dangers posed by the milling machine
The milling machine was built using state-of-the-art technology.
Nevertheless, there is a residual risk, as the milling machine operates with
high speeds,
circulating parts and tools and
electrical voltage and currents.
We have used design and safety engineering to minimize the health risk to personnel resulting
from these hazards.
If the milling machine is used and maintained by personnel who are not duly qualified, there
may be a risk resulting from its incorrect or unsuitable maintenance.
INFORMATION
Everyone involved in the assembly, commissioning, operation and maintenance must
be duly qualified,
and strictly follow these operating instructions.
Always disconnect the milling machine from the electrical power supply before performing
cleaning or maintenance tasks.
WARNING!
The milling machine may only be used with fully functional safety devices.
Disconnect the milling machine immediately, whenever you detect a failure in the safety
devices or when they are not fitted!
All additional devices installed by the operator must be equipped with the stipulated
safety devices.
This is your responsibility being the operating company or private user!
EN
MH50G│MH50V
64
C1
C2
Residential area
Business area
Industrial area
< 1000 V
no requirement
Installation and commissioning by an EMC expert
Translation of original instruction
C3
C4
Industrial area
> 1000 V
Version 1.0.5 - 2021-01-29

Werbung

loading

Diese Anleitung auch für:

Optimill mh 50vOptimill mh 50g3338185