Parameter
Unit
E
Decimal places
Measuring range start
Measuring range end
Digital flag
The following configuration parameter is available for both of the two digital flags.
Parameter
Digital flag
10.5 Math/Logic
NOTE!
This function is available in the setup program if the „Math/logic" extra code has been activated (Hard ware assistant >
Device configuration: Math/logic). To access this function in the device, it must be en abled with the setup program (CPU:
Online parameters > Enabling of extra codes).
This optional math and logic function can be used to link analog (math) or binary (logic) values. Four configurable for-
mulae can be created for this.
The following configuration parameters are available for each of the four formulae. Use the „Formula ed itor" button to
open an editor that can be used to create formulae by selecting variables and operators.
Parameter
Function
Temperature
Unit
Start of display range
Display range end
Selection/text/value
<Enter text>
%
Auto
XXXX.
XXX.X
XX.XX
X.XXX
-1999 to 9999 (0)
-1999 to 9999 (100)
Selection/text/value
Off
On
Selection/text/value
Without function
Math formula
Logic formula
None
Relative
Absolute
<Enter text>
%
-1999 to 9999 (0)
-1999 to 9999 (100)
Product:
Temperature controller XT-T1
Description
Value unit (if it is not a temperature)
Decimal places for the numerical display of the val ue
Automatic
No decimal place
One decimal place
Two decimal places
Three decimal places
Minimum admissible value
Maximum admissible value
Description
„Low" binary value
„High" binary value
Description
Function is switched off.
Mathematical link with freely selectable variables and
operators
Logical link with freely selectable variables and op erators
This selection is important for the automatic con version
in case of a change in temperature unit (°C/°F) (see
system data).
The result is not a temperature.
The result is a temperature difference.
The result is a temperature value.
Result unit (if it involves a temperature)
Lower limit of display range
Upper limit of display range
Revision 2.0 – Issue September 2018