Parameter
Restart signal
Output signal
Tolerance band
Tolerance band actual value Analog selector
Tolerance band setpoint
value
Additional functions
(setup only)
Timer signals
Timer output: The signal is active from the start until the timer elapses (high active or low active configu rable).
Tolerance band signal timer: The signal is active if the actual value before the timer start is outside the valid range.
If the actual value after the timer starts runs out of the valid range, the timer time is only stopped (timer stop signal
active) until the actual values reaches the valid range again! The tolerance band signal is not active in this case.
End signal timer: The signal is active after the timer elapses for the duration of the after-run time (or until acknow-
ledgement).
Stop signal timer: The signal is active while the timer is stopped.
Timer symbol (display)
Off: Timer is not active (function = off)
Lights up: Timer is active (function = on)
Flashes: Timer is active and running (symbol also flashes during lead time, if timer has stopped, and during after-run
time)
Behaviour after power down
The timer output signals are inactive during the device's initialization phase. The runtime and remaining running time
are saved via power off on the device. The behavior after power on is configurable.
Product:
Temperature controller XT-T1
Selection/text/value
Digital selector
No selection
High active
Low active
0 to 9999
No selection
Analog selector
No selection
Expansion 1
Revision 2.0 – Issue September 2018
Description
Signal (active for rising edge) to reset and restart the
timer
The restart signal only works during the runtime (not
during the lead time or after-run time); it can not be used
to start the timer.
The lead time is not considered in case of a restart.
Output signal: high active while timer is running
Output signal: low active while timer is running
Standard tolerance band (in Kelvin) around the setpoint
value
After the timer is started, the timer time only runs from
the point in time when the actual value reach es the
tolerance band.
0 = Start without tolerance band
Actual value for tolerance band function
Setpoint value for tolerance band function
Reserved function for service purposes. Only acti vate
when instructed to do so by service person nel!