 Remove the piezometer. Fully open the plunger of the liquid valve and gas valve with the inner hex
key.
 Tighten the screw caps of the valves and refrigerant charge port.
 Reinstall the handle.

Leak detection

Check for leaks using a leak detector. If you do not have a leak detector you can use soapy water.

Post-installation checks

Has the unit been installed securely?
Has the leakage test of the refrigerant been done?
Is the thermal insulation of the pipes sufficient?
Does the water drain properly?
Does the supply voltage match the voltage indicated on the
data plate?
Have the piping and electrical wiring been installed
correctly?
Has the unit been properly earthed?
Does the power cable meet requirements?
Are there any obstructions at the air inlet or outlet?
Have the dust and other particles produced during
installation been removed?
Are the gas valve and liquid valve of the connecting tube
fully open?
The entrance and exit of the pipe holes have been covered? Risk of condensation and dripping water.

TESTING AND OPERATION

Functional testing

Connect the power and press the ON/OFF
Press the MODE button to select AUTO, COOL, DRY, FAN and HEAT mode and check the air conditioner
operates normally.
If the ambient temperature is below
Checks
button on the remote control to start operation.
16°C, the air conditioner will be unable to start cooling.
The unit could fall, move or produce excessive noise.
Risk of condensation and dripping water.
Risk of condensation and dripping water.
Risk of condensation and dripping water.
Risk of malfunction or damage to components.
Risk of malfunction or damage to components.
Risk of electric leakage.
Risk of malfunction or damage to components.
The cooling (heating) capacity may be insufficient.
Risk of malfunction or damage to components.
The cooling (heating) capacity may be insufficient.