Step five: connect the outdoor electrical cable
1. Remove the wire clip. Connect the power cable and the signal control cable (only for cooling and
heating units) to the wiring terminal according to colour.
2. Secure the power cable and the signal control cable with the clip (only for cooling and heating units).
N.B.:
• Once you have tightened the screw, pull on the power cable gently to check it is secure.
• Never cut the power cable to extend or reduce the distance.
Step six: tidy up the pipes
1. The pipes should be routed along the wall, bent only
as much as is necessary and, if possible, hidden from
view. Minimum pipe bending radius: 10 cm.
2. If the outdoor unit is higher than the hole in the wall,
you must create a U-bend in the pipe before it enters the
room to prevent rain from getting into the room.
Secure them with the screws.