80
COF
0
2
4
6
7
8
Meaning of the abbreviations:
MSB
B
LSB
st
CR
LF
NOTE
Arbitrary values between 0 and 255 can occur in the binary output. Therefore the
ASCII codes for carriage return (0x0D), line feed (0x0A) and "NUL" (0x0), which are
frequently used for end detection, can also be contained. The receiving software must
therefore be set up for the fixed byte number of the answer and may not search
through the answer bytes for end characters.
Meaning of the status byte
In some output formats a status byte follows on the measured value. It is used according to
unit status for outputting different information. The highest bit (MSB) serves for differentia-
tion. In the case of errors (ErrXX in the display) MSB = 0 and the value of the bytes (0...99) is
equal to the error number XX. In undisturbed operation MSB = 1, the other bits are status
bits which then describe the scale status.
Bit 7
1
0
HBM
Byte0
Byte1
MSB
B
MSB
LSB
0
LSB
LSB
MSB
st
LSB
MSB
B
Most significant bit
Middle bit
Least significant bit
Status byte
End character 1 (factory setting: carriage return)
End character 2 (factory setting: line feed)
Bit 0..6
Meaning
Status messages
0
1 = Gross value outside display limits
1
0 = Gross
1 = Net
2
1 = Scaling too sensitive
3
1 = Standstill
4
1 = Limit1 active
5
1 = Limit2active
6
In two−range / two−division scale:
0 = Scale is in range 1
1 = Scale is in range 2
In counting scale:
0 = Weight display
1 = Count display
Error number as in the display (ErrXX)
0..6
Error code XX (binary 0...99)
Byte2
Byte3
LSB
0
CR
LF
B
MSB
CR
LF
B
MSB
LSB
st
Scale electronic unit (NSW)
Byte4
Byte5
CR
LF
CR
LF
CR
LF
CR
LF
WE2108