If no temperature sensor is fitted, the heat pump must be used to ensure the mi-
nimum temperature is met. As an alternative, the Ohmpilot can also ensure the
minimum temperature by activating the heat pump. This may result in electricity
being sourced from the grid. The maximum temperature must be set on the hea-
ting element thermostat and on the heat pump. If the heating element does not
have a thermostat, the Ohmpilot can also carry out this task as an alternative
(see chapter
This function can also be combined with a 3-phase heating element.
Settings in the
menu area
1
2
3
4
Example 1: If "Consume" has been selected under the switch-off threshold and a
power of 500 W has been entered, the heat pump will be switched off as soon as
the power being drawn from the grid exceeds 500 W.
Heat pump COP. The higher the temperature to which the hot water is hea-
ted, the lower the COP.
The electrical heat pump output.
The feed-in tariff and the costs for purchasing energy.
Reduction of the heat pump's start-up cycles = increase in service life of the
heat pump.
Thermal losses from the heat pump and the pipes.
Optional settings
Open the Ohmpilot user interface
Chapter
Establishing the data connection
can access the Ohmpilot user interface.
Under
HEATER 2
for consumer, select
Select "Feed-in" under
watts at which the heat pump is to be switched on.
Under
Switch-off
threshold, select "Consume" or "Feed-in" and enter the
desired output in watts at which the heat pump is to be switched off.
on page 122).
on page
"SG Ready heat
Starting threshold
and enter the desired output in
113
describes how you
pump"
99