Choice of location and installation position

Choosing locati-
Please note the following criteria when choosing a location for the Ohmpilot:
on - general re-
marks
Install only on a solid surface.
If the Ohmpilot is installed in an enclosed space, then forced-air ventilation
must be provided to ensure adequate heat dissipation.
IMPORTANT! The maximum cable length from the output of the Ohmpilot to
the load (heating element) must not exceed 5 m.
Choice of locati-
on
The Ohmpilot is suitable for installation indoors.
Do not install the Ohmpilot outdoors.
The housing complies with protection class IP 54 and is protec-
ted against spray water from all sides.
In order to minimise the heating up of the Ohmpilot, do not ex-
pose it to direct insolation. Mount the Ohmpilot in a protected
position. The Ohmpilot must only be mounted and operated at
an ambient temperature of 0-40 °C.
IMPORTANT! The Ohmpilot must not be installed or used at al-
titudes above 2000 m.
Max. ambient temperatures:
0 °C / +40 °C
Relative humidity:
0 - 99%
The airflow within the Ohmpilot is
from the bottom to the top.