Optional settings
Manual settings
NOTE!
for HEATER 1
Settings not absolutely necessary.
The settings described here can be made for all the application examples shown
above. If they are not described for the respective example, they are not abso-
lutely necessary.
Setting the output of HEATER 1 manually:
1
2
3
NOTE!
It is not possible to measure heating element 1 automatically.
In the case of applications with a 1-phase and a 3-phase heating element, it is
not possible for the Ohmpilot to measure heating element 1 automatically due to
the cabling. In this case, the configuration must be carried out manually.
Activating legio-
When the legionella prevention function is activated, the hot water is heated to
nella prevention
60 °C at a set interval.
122
Under
HEATER
1, select "Manual"
Select "Single-phase" or "Three-phase"
Enter the output of the load
Consumer