Check the electrical connection cables for damage
regularly. Ensure that the connection cables are dis-
connected from electrical power when checking for
damage.
Electrical connection cables must comply with the ap-
plicable VDE and DIN provisions.
Only use connection cables with the marking
H 05 VV-F.
The printing of the type designation on the connection
cable is mandatory.
AC motor
The mains voltage must be 220-240 V~.
Extension cables up to 25 m long must have a
cross-section of 1.5 mm
.
2
Connections and repair work on the electrical equip-
ment may only be carried out by electricians.
Please provide the following information in the event
of any enquiries:
• Type of current for the motor
• Machine data - type plate

11. Transport

• Transport the electric tool by lifting it on the recesses
provided for this on the frame and the motor cover.
• Never use the protective devices for handling or
transport.
• Make sure that the exposed part of the saw blade
is covered during transport, e.g. by the protective
device.
12. Cleaning, maintenance and
ordering spare parts
m WARNING
Always switch the machine off and remove the mains
plug prior to all maintenance and cleaning work.
12.1 Cleaning
Keep protective devices, air vents and the motor hous-
ing as free of dust and dirt as possible. We recommend
cleaning the device directly after every use.
12.1.1 Exterior cleaning
• Clean the device at regular intervals using a damp
cloth and a little soft soap.
• Do not use cleaning agents or solvents. These could
damage the plastic parts of the device.
34 | GB
• Make sure that no water can penetrate the device
interior.
12.1.2 Interior cleaning (fig. 15)
1.
Open the storage box (9).
2.
Remove the screw (34).
3.
Loosen the screw (33).
4.
Remove the cover (8).
5.
Blow out the device interior with low-pressure
compressed air.
6.
Attach the cover again (8).
7.
Fasten the screw (33).
8.
Insert the screw (34) again and tighten it.
9.
Close the storage box (9).
12.2 Maintenance
12.2.1 Bearings (fig. 1/item 10)
Lubricate the bearing points (10) of the deflection roll-
ers after approx. 25-30 operating hours at the latest
using high-quality machine grease.
12.2.2 Carbon brushes
If excessive sparks are generated, have an electrician
check the carbon brushes.
ATTENTION
The carbon brushes must only be replaced by an elec-
trician.
12.2.3 Mains cable
If the mains cable is pulled out, cut, or damaged in
some other form, then it should be replaced immedi-
ately.
12.2.4 Replacing the fine-wire fuse (Fig. 16)
If the fine-wire fuse (7) is defective, it must be replaced
with a fine-wire fuse of the same type 5 A/250 V
(ø 5 x 20 mm).
m WARNING
Do not bypass the fine-wire fuse (7)! Do not use fus-
es of any other type! This can lead to damage to the
device.