Herunterladen Inhalt Inhalt Diese Seite drucken

Reasonably Foreseeable Misuse - Optimum Optidrill B 24H Betriebsanleitung

Vorschau ausblenden Andere Handbücher für Optidrill B 24H:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

1.3

Reasonably foreseeable misuse

Any use other than that specified under "Intended use" or any use beyond that described will be
deemed non-intended use and is not permissible.
Any other use must be discussed with the manufacturer.
It is only allowed to process metal, cold and non-inflammable materials with the drilling
machine.
In order to avoid misuse, it is necessary to read and understand the operating instructions
before first commissioning.
Operators must be qualified.
INFORMATION
The drilling machine for regulating the speed is built according to the standard EN 61800-3
class C2.
WARNING!
This machine is not intended for use in residential buildings, in which the power supply
is provided via a public low voltage supply system. In these areas it may possibly be
difficult to guarantee electromagnetic compatibility due to lead bound as well as emitted
interferences.
Overview of the EMC categories:
Categorie C1
required limit values Class B Group 1 according to EN 55011
Categorie C2
Required limit values class A Group 1 according to EN 55011, Installation by EMC experts
and warning: "This is a product of category C2 according to EN 61800-3. This product may
cause radio interference in a residential area. In this case, it may be necessary for the ope-
rator to take appropriate action."
Categorie C3
Required limit values class A group 2 according to EN 55011, whereby these limit values
are below those of class A group 1, plus warning: „This type is not suitable for connection to
a public low-voltage network supplying residential buildings. When connecting to a public
low voltage network, radio frequency interference is expected. "
Machine
B24HV and B28HV
Categorie
Environment
Voltage / Current
EMC knowledge
GB
B24H | B24HV | B28H | B28HV
80
C1
C2
Residential area
Business area
Industrial area
< 1000 V
no requirement
Installation and commissioning by an EMC expert
Translation of the original instructions
C3
C4
Industrial area
> 1000 V
Version 2.2.6 - 2020-07-21