19 Messages

19.1 Error messages

Faults can be reset by switching off
i i
and on again.
Code
Fault
E01-01 Excess temperature
E01-02
E01-05
E02-00 Overvoltage, primary Mains voltage too high
E02-01
E02-02
E04-05 PFC error
E06-00 Overvoltage second-
ary
E07-01 Internal EEProm fault
E11-00 Fault in remote con-
trol
E12-00 Fault in Power unit
E13-01 Thermal sensor
E13-02
E14-00 Primary undervoltage internal supply voltage too low
E14-01
E15-00 Current measurement Error in internal power measure-
E15-01
- 36 -
Possible cause
The device has overheated, the
permitted switch-on time was
exceeded
Internal working voltage too
high
Internal mains control not work-
ing
Initial voltage too high
Internal accummulator faulty
Defect in remote control or
remote control socket
Power section start-up faulty
Internal temperature sensor
defective
Internal operating voltage too
low when powering on
ment
909.4119.9-02
As long as there is an error code on dis-
i
play welding is not possible.
Allow switched-on machine to cool
down for a few minutes.
Check mains voltage, test device on
another power socket.
Switch the equipment off and on
again. Inform the customer service
in the event of a repeated or perma-
nent fault message
Check the work piece. Inform the
customer service in the event of a re-
peated or permanent fault message
Switch the equipment off and on
again. Inform the customer service
in the event of a repeated or perma-
nent fault message
Check or replace the remote control
Switch the equipment off and on
again. Inform the customer service
in the event of a repeated or perma-
nent fault message
Check mains voltage, test device on
another power socket. Switch the
equipment off and on again. Inform
the customer service in the event
of a repeated or permanent fault
message
Check torch and work piece con-
nections. Switch the equipment off
and on again. Inform the customer
service in the event of a repeated or
permanent fault message