Herunterladen Inhalt Inhalt Diese Seite drucken
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 1
17.2

Error messages

If the error occurs again, an inspection or repair
i i
by the service office is necessary.
Code
Error
Thermal overload secondary
E01-01
diode
Thermal overload primary mod-
E01-02
ule
E01-03
Thermal overload transformer
E01-05
Thermal overload PFC
E02-00
Overvoltage mains
E04-01
PE conductor monitoring
Water pump (in water-cooled
operation)
E05-00
Torch monitor (in gas-cooled
operation)
E06-00
Overvoltage secondary
E09-00
Voltage detection
E09-01
Voltage detection plug socket
E10-00
Torch/remote control
E10-01
Thermal overload torch
E12-00
Power section
Temperature sensor secondary
E13-01
diode
Temperature sensor primary
E13-02
module
E13-03
Temperature sensor transformer
E13-04
Temperature sensor PFC
E14-00
Supply voltage
E15-00
Current detection
E16-00
Overcurrent protective switch off
E19-00
Ignition device
E22-00
Low voltage mains
E25-00
Voltage Reduction Device (VRD)
E30-00
Error configuration
E30-03
User panel identification
E33-01
Power unit
E34-00
Fan
Tab. 10:
Error messages
- 48 -
Cause
Duty cycle exceeded
Mains voltage too high
Fault current to protective earth conductor
Connection cable or machine water cool-
ing circuit defective
Incorrect torch connected (water-cooled
torch)
Initial voltage too high
Error at voltage detection
Error at the voltage detection module 2
Remote control, torch or connections
defective
Torch stressed beyond-design limit
Power section start-up faulty
Thermal sensor defective
Fault internal supply voltage
Error at the current detection
Current consumption of power unit too
high
Ignition unit faulty
Mains voltage too low
Voltage Reduction Device defective or
short circuit between workpiece and torch
Wrong or broken pc-board, wrong system-
software was flashed
User panel identification error
Power unit not symmetrical
Fan current to high
909.2669.9-02
Possible remedy
Allow switched-on machine to cool down for a
few minutes.
Check mains voltage
Check connection of the workpiece cable and
ground clip
Check and replace Lorchnet cable or machine
water cooling
Use gas-cooled torch (recognised by bridge be-
tween the contacts 4 and 5 on the torch plug)
Inform Service
Check or replace torch and remote control
Allow torch to cool down for a few minutes
Inform Service
Check mains voltage
Torches and electrode holders must not have
electrical contact to the ground cable (short
circuit) when switched on
Inform Service
Messages
01.21

Quicklinks ausblenden:

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis