Herunterladen Inhalt Inhalt Diese Seite drucken

Secondary Parameters - LORCH MicorStick 180 ControlPro Bedienungshandbuch

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 1

Secondary parameters

16 Secondary parameters
 Call up the secondary parameters by pressing
button 19 for 2 sec.
 Set the desired secondary parameter by turn-
ing control knob 14.
‰ A description of the secondary parameters is
provided in the following table.
 Confirm the secondary parameter by pressing
control knob 14.
Code
Secondary parameters
Start energy
StE
Hot start energy
Start time
Stt
Hotstart time
StS
Start slope time
PuO
Pulse Option
2.E
Second energy
PuF
Pulse frequency
Pub
Pulse duty cycle (% of welding current I1)
dAF
Arc Force
AEd
Arc end detection
Tab. 1:
Secondary parameters
07.19
9 The parameter value flashes.
 Change the value of a parameter by turning
control knob 14.
 Store the change by pressing control knob 14.
‰ Press button 19 to terminate a change with-
out storing or to exit the secondary parameter
menu.
Standard
value
50 %
125 %
0.1 s
1.0 s
0.5 s
OFF
50 %
3.0 Hz
50 %
100 %
100 %
909.4119.9-02
Setting range
1 - 200 %
1 - 200 %
0 - 99.9 s
0 - 99.9 s
0 - 99.9 s
OFF - On
1 - 200 %
0.1 Hz - 5 kHz
1 - 99 %
0 - 200 %
0 - 200 %
Mode
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
- 33 -

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

Micorstick 180 rc controlpro

Inhaltsverzeichnis