Technical data
Voltage
Break-off capacity
Power consumption
Application range
Low temperature range
High temperature range
Roof sensor, moisture
Connection cable
Loading
Connection difference
Encapsulation class
Reserve power
Max length, sensor cable
Alarm relay
Installation
Ambient temperature
Test value for NTC sensor
-10 °C
0 °C
+10 °C
+20 °C
+25 °C
Certification: EMC/2500 VAC RoHS WEEE CB
Unit dimensions drawing
35
230 VAC +/- 10 % ~ 50 Hz
3680 W/16 A/230 VAC
2.5 W
-20 °C to +150 °C divided into two ranges
-20 °C to +75 °C – Sensor type NTC
0 °C to +150 °C – Sensor type PTC
24 VDC, NO
max 2.5mm²
cos φ = 1
Adjustable +/- 0.3 to 10.3 °C
IP20
50 hours
50 m, 2x1.5 mm²
2 A/120 VAC Normal connection
Standard DIN-rail EN 50022-35
-20 °C to +45 °C
Test value for PTC sensor
42.5 kΩ
+70 °C
27.3 kΩ
+90 °C
18.0 kΩ
+110 °C
12.1 kΩ
+130 °C
10.0 kΩ
+150 °C
1392 Ω
1591 Ω
1805 Ω
2023 Ω
2211 Ω
90
35