Herunterladen Inhalt Inhalt Diese Seite drucken

EBECO EB-Therm 800 Handbuch Seite 53

Multifunktionaler digitalthermostat mit vier betriebsmodi für die din-montage
Vorschau ausblenden Andere Handbücher für EB-Therm 800:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

thermostat is set as a floor thermostat, this is the temperature that you set in the
TEMP menu and not the temperature in the room or on the surface of the floor.
ROOM THERMOSTAT
If the room is very large or has large areas of glass, it can sometimes be better to
regulate the heating via a room sensor. A complementary sensor (E 85 816 22) is
then
required.
When the thermostat is set as a room thermostat, it is the room tem-
perature that is set in the TEMP menu.
ROOM THERMOSTAT WITH OVER HEATING PROTECTION
If you have a wood or laminate floor, you must use this installation to safeguard
the floor material against over heating and damage. The preset temperature
limitation setting is +35 °C. Read more about over heating protection in the section
Temperature menu. A complementary sensor (E 85 816 22) is then required.
Reset
RESET
There are three choices under the reset menu: CONN TIME, OP MODE and FAC
SET. You will find the RESET menu under SYSTEM in the MAIN MENU.
Reset connection time
CONN TIME
The connection time is shown in hours; as with a vehicle trip meter, it shows the
number of hours an installation has been connected for since it was last reset. This
is beneficial if you want to calculate the energy consumption for a certain period.
The thermostat also has a counter that cannot be reset, which shows the total hours
the installation has been connected for.
To see the total and momentary connection times, press when the thermostat is in
display mode.
The reset function is in the SYSTEM menu under RESET; from here, select CONN
TIME. This is preset to NO and is changed to YES by pressing
with
.
Reset the operation mode settings
You can reset the settings in OP MODE HEATING. All programs are reset and the
temperature and sensor settings return to the output values. Resetting does not
affect the choice of OP MODE, LANGUAGE or setting for DATE/TIME.
The reset function is in the SYSTEM menu under RESET, and there select CONN
TIME. This is preset to NO and is changed to YES by pressing
with
.
Reset factory settings
FAC SET
The thermostat can be entirely reset to factory settings. All programmed data is
deleted and the start up menu is opened. If you choose to reset the thermostat, it is
important to know the operation mode it uses and the configuration of the sensors.
The only way to change operation mode is to reset to the factory settings.
The reset function is in the SYSTEM MENU under RESET; from here select FACTORY
SETTINGS. This is preset to NO and is changed to YES by pressing
ing with
.
OP MODE
and confirming
and confirming
and confirm-
17

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis