Error messages

Drive system

Display
E02
E05
E06
E07
E08
E09
E21
E22
E23
E30
E32
page 94 / 113
Cause
Stator excess temperature (motor overheated)
Motor/propeller blocked
Voltage to motor is too low
Overcurrent to motor
Circuit board excess temperature
Water ingress to pylon
Incorrect calibration of accelerator lever
Magnetic sensor defective
Value range incorrect
Communication error with motor
Communication error for accelerator lever
Troubleshooting
After waiting for a short period (approx. 10 minutes), motor can be
operated slowly again.
Contact Torqeedo Service.
Put the main switch into the "OFF" position, and disconnect the batteries.
Release the blockage, and turn the propeller one further turn by hand.
Reconnect the batteries to the system.
Low state of charge of battery. It may be possible to restart the motor
slowly from the Stop position.
Continue at reduced power.
Contact Torqeedo Service.
After waiting for a short period (approx. 10 minutes), motor can be
operated slowly again.
Contact Torqeedo Service.
Contact Torqeedo Service.
See accelerator lever manual.
See accelerator lever manual.
See accelerator lever manual.
Check the plug connections of the data cables. Check the cables. If
necessary, contact Torqeedo Service and inform them of the error code.
Check the plug connections of the data cables.
Check the cables.