Care and service
9.3

Maintenance intervals

Servicing is to be carried out only by Torqeedo Service or authorised service partners, according to elapsed time or operating hours, as specified. The activities before each use
and the change of anodes can be carried out independently.
If the prescribed maintenance intervals are not complied with or documented, this leads to loss of warranty. Ensure that the services carried out are documented in your
service check folder.
Service activities
Batteries and battery cables
Other screws and bolts on the
Cruise system
Cable connections
Electronic accelerator lever
O-rings
Gear shaft
Galvanic anodes
Before each use
Confirm full insulation
Visual inspection
Secure against slipping and tipping
over
Check that threaded cable
connections are screwed tight
Check tight fit
Confirm full insulation
Check that threaded cable
connections are screwed tight
Check stability
Check functioning
Visual inspection
Visual inspection
Every 6 months or after 100 operating
hours
Replace as complete sets
EN
DE
Every 5 years or after 700 operating
hours (whichever occurs first)
To be checked by a certified service
partner
To be checked by a certified service
partner