Herunterladen Inhalt Inhalt Diese Seite drucken

Bosch Rexroth CSS/B Betriebsanleitung Seite 61

Bandstrecke
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

3 842 539 952/2011.02 | TS 2pv
6.11.2
Drive with frequency converter (FC)
• The motor data must be entered in order to infi nitely control the
transportation speed of a drive with a frequency converter (FC).
• All parameters can also be entered via the function keys on the display. A
detailed description of the parameters can be found in the Bosch Rexroth
IndraDrive Fc documentation: R911 310 782.
• Depending on the version, the frequency converter can be operated with
a voltage of 200-240 V or 380-480 V.
For further technical data, see the Bosch Rexroth IndraDrive Fc
documentation: R911 310 782.
NOTICE
Malfunctions due to incorrect entry or commissioning
The motor may be damaged or its service life shortened.
Do not deviate from the stipulated motor data as this can result in
damage to the motor.
Minimum wiring
• Minimum wiring must be established for the power supply and control
unit (see "Fig. D: Motor connection, minimum wiring" on page 24).
• The maximum motor cable length may not exceed 20 m.
• Only use shielded motor connection cables that have been approved for
the operation of frequency converters.
Bosch Rexroth AG
23/38

Werbung

Inhaltsverzeichnis

Fehlerbehebung

loading

Diese Anleitung auch für:

Rexroth css/bmRexroth css/fRexroth css/fm

Inhaltsverzeichnis