Herunterladen Inhalt Inhalt Diese Seite drucken

Fault Diagnosis - Bosch Servodyn-ASC Betriebshandbuch

Steuerkarte
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

Servodyn - ASC

Fault Diagnosis

4.7 Fault Diagnosis
Display
GB
GB - 52
Fault
Underpotential
Overpotential
Overcurrent
Overheat
no Overheat
Overload
no Overload
Drive Overheat
External Fault
Power Unit Code
Prohibited rotation
forward
Prohibited rotation
reverse
Hybrid
digital signal processor
Ladeshunt fault
Description
Occurs when the dc-bus voltage drops below
the permissible value.
Occurs when the dc-bus voltage rises above
the permissible value.
Occurs when the output current exceeds the
permissible value.
Occurs when the heat sink temperature is >
90°C. The message E.nOH appears, when the
overheating error is no longer present.
Occurs when an overload is present for longer
than the permissible time.
The message E.nOL appears after the cooling
phase. (see curves in the instruction manual
part 2).
Occurs 60 s after the temperature monitoring is
triggered.
Occurs when parameter CP.15 = 0 the digital
input I3 is activated.
______
Occurs when the rotation release on terminal
X2.3 and/or X2.4 is not present and parameter
CP.35 = 0.
Speed measurement card missing or defective.
Processor - fault
Occurs when the input voltage is too low after
startup or the ladeshunt fault didn't switch.
(Monitoring with ladeshunt relais not possible
with all unit sizes).
1070066022 - 101

Werbung

Kapitel

Inhaltsverzeichnis
loading

Inhaltsverzeichnis