Steuerkarte
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

Torque level
Output D1
Speed level
Output D2
Rated Motor Power
Rated Motor Speed
Rated Motor Current
1070066022 - 101
Defines the torque level of the digital output D1.
Adjustment Range :0 ... 1000 Nm
Resolution:
Factory setting:
max. Tolerance:approx. ±20 % in base speed range
(in the field wakening range larger tolerances are possible)
During open loop operation (CP.32 = 0) the value for the motor
torque is set at 0.
Defines the speed level of the digital output D2.
Adjustment Range:0 ... 9999,5min
Resolution:
Factory setting:
The rated motor power of the connected motor must be adjusted in
CP.25 .
Adjustment Range:0,01 ... 75 kW
Resolution:
Factory setting:
dependent on size
The rated motor speed of the connected motor must be adjusted in
CP.26 .
Adjustment Range:100 ... 6000min
Resolution:
Factory setting:
dependent on size
The rated motor current of the connected motor must be adjusted in
CP.27 .
Adjustment Range:
dependent on size
Resolution:
Factory setting:
dependent on size
Servodyn - ASC
Parameter Adjustment
0,1 Nm
0 Nm
-1
0,5 min
-1
0 min
-1
0,01 kW
-1
-1
1 min
0,1