Parameter Adjustment
Change Encoder 1
Rotation
GB
Reaction to Limit Switch
GB - 46
Parameter CP.34 adjusts the direction of rotation of the encoder.
Adjustment Range:
Resolution:
Factory setting:
0 = track not exchanged
1 = track exchanged
This parameter determines the reaction of the drive, to terminal X2.3
(F) and/ or X2.4 (R). These terminals can be programmed as software
limit switches. The reaction of the drive is shown in the table below.
Adjustment Range:
Resolution:
Factory setting:
Value Error / Status
massage
0
E.PrF
E.Prr
1
A.PrF
A.Prr
2
A.PrF
A.Prr
3
A.PrF
A.Prr
4
A.PrF
5
A.PrF
A.Prr
6
keine
Quick stop
0 ... 1
1
0
0 ... 6
1
6
Response of the drive
modulation immediately switched off
! To restart remove error and activate
Reset !
quick stop /modulation switched off
after speed 0 is reached
! To restart remove error and activate
Reset !
quick stop / holding torque at speed 0
! To restart remove error and activate
Reset !
modulation immediately switched off
! Automatic Restart, when error is no
longer present !
quick stop / modulation switched off after
speed 0 is reached
! Automatic Restart, when error is no
longer present !
quick stop / holding torque at speed 0
! Automatic Restart, when error is no
longer present !
no effects on the drive
! Fault is ignored !
⇒ ⇒ ⇒ ⇒ ⇒
deceleration at the torque limit
(CP.9)
1070066022 - 101