Herunterladen Inhalt Inhalt Diese Seite drucken

Bosch Servodyn-ASC Betriebshandbuch Seite 97

Steuerkarte
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

Servodyn - ASC
Operating Display
Operating Display
Operating Display
Operating Display
Operating Display
Speed Reference Display
GB
Acceleration Time
GB - 32
Displays the speed reference at the output of the ramp generator in
rpm.
When the modulation is switched off the setpoint 0 rpm is displayed.
Resolution: 0,5 rpm
positive speed:
direction of rotation "forward"
negative speed:
direction of rotation "reverse"
n
[rpm]
Defines the time needed to accelerate from 0 to 1000 rpm. The actual
acceleration time is proportional to the speed change (
Adjustment Range:
Resolution:
Factory setting:
n [rpm]
1000
800
∆ n
300
∆ t
0
0,5
1
1,5
CP.7
Example:
The drive should accelerate from 300 rpm to 800 rpm in 1 s.
∆ ∆ ∆ ∆ ∆ n = 800 rpm - 300 rpm = 500 rpm
∆ ∆ ∆ ∆ ∆ t = 1 s
∆ t
CP.7 =
x 1000 rpm
∆ n
Analog Setpoint Input
acceleration time
0...320
s
0,01
s
2,0
s
∆ n
speed change
∆ t
acceleration time for ∆ n
CP.7 =
t [s]
2
1 s
=
500 rpm
t [s]
n).
∆ t
x 1000 rpm
∆ n
x 1000 rpm = 2 s
1070066022 - 101

Werbung