Herunterladen Inhalt Inhalt Diese Seite drucken

Bosch Servodyn-ASC Betriebshandbuch Seite 90

Steuerkarte
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

3.3.3 Connection X5
Option
1070066022 - 101
2- Output signals:
Two square-wave pulses that are electrically by
90° out of phase and their inverse signals
A+
A-
B+
B-
or
Two sinusoidal incremental signals that are
electrically by 90° out of phase and their inverse
signals
A+
A-
B+
B-
3- Increments:
The 9-pole sub-D-socket is used for options.
For Connection and Startup see Parameter Manual!
5
4
3
2
1
9
8
7
6
Rectangular Signal
sinusoidal 1 Vss-signals
256 - 10000 inc. (recommended: 2500 inc.)
cut-off frequency of the interface: 200 kHz
Observe the cut-off frequency of the encoder:
increments • n
f
>
————————
limit
60
Signal
- dependent on the option -
Servodyn - ASC
Control Circuit
Control Circuit
Control Circuit
Control Circuit
Control Circuit
2...5 V
0 V
U0 + 0,5 V (+/-20 %)
U0 ⇒ approx. 2,5 V
U0 - 0,5 V (+/-20 %)
max
rpm
PIN-No.
GB - 25
GB