Herunterladen Inhalt Inhalt Diese Seite drucken

Startup - Bosch Servodyn-ASC Betriebshandbuch

Steuerkarte
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

Servodyn - ASC

Startup

4.8 Startup
For the initial startup of BOSCH ASC do the following:
1. Switch off control release (terminal X2.1) ⇒ ⇒ ⇒ ⇒ ⇒
GB
2. Select controlled operation
3. Enter motor data
4. Activate Load motor dependent parameter ⇒ ⇒ ⇒ ⇒ ⇒
5. Enter necessary boost
6. Enter encoder (inc/r)
7. Observe cut-off frequency of encoder
8. Startup in controlled operation
GB - 54
Start
Preset positive set speed
REF1 (terminals X2.14/X2.15)
Activate control release
(terminal X2.1)
Is the
dir. of rotation of
the motor (forward)
correct
?
YES
Is the
sign of the actual
speed display
(Par. CP.1)
positive
?
YES
Actual
speed (CP.1) = set
speed (CP.6)
minus slip
?
YES
Initial start-up successful!
Inverter in status „noP"
⇒ ⇒ ⇒ ⇒ ⇒
Parameter CS.23
⇒ ⇒ ⇒ ⇒ ⇒
Parameter CP.25...CP.30
(see page GB 43/44)
Parameter CP.31
⇒ ⇒ ⇒ ⇒ ⇒
Parameter CP.33
⇒ ⇒ ⇒ ⇒ ⇒
Parameter CP.14
⇒ ⇒ ⇒ ⇒ ⇒
See page GB 25
⇒ ⇒ ⇒ ⇒ ⇒
See diagram below
Remove cause of error
NO
Exchange motor phases
NO
Exchange encoder tracks
(Parameter CP.34)
NO
Possible causes: encoder defective,
interface defective, EMC-problems,
cut-off frequency of the encoder is
too small.
1070066022 - 101