Herunterladen Inhalt Inhalt Diese Seite drucken

Bosch Servodyn-ASC Betriebshandbuch Seite 109

Steuerkarte
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

Servodyn - ASC
Parameter Adjustment
Rated Motor Frequency
GB
Rated Motor cos (Phi)
Rated Motor Voltage
Load motor depending
parameter
GB - 44
The rated frequency of the connected motor must be adjusted in
CP.28 .
Adjustment Range: 20 ... 300
Resolution:
Factory setting:
dependent on size
The rated power factor of the connected motor must be adjusted in
CP.29 .
Adjustment Range:
Resolution:
Factory setting:
dependent on size
The rated voltage of the connected motor must be adjusted in
CP.30 .
Adjustment Range:100 ... 500
Resolution:
Factory setting:
The basic settings of the inverter correspond to the size of the unit and
the respective motor (see table on page GB 48). If the motor data in
CP.25...CP.30 are changed, then CP.31 must be actived once. This
re- adjusts the current controller, torque curve and torque limit. With this
the torque limit is set at the value, that is maximally possible in the
speed range (dependent on inverter rated current).
Adjustment Range:
Resolution:
Factory setting:
When control release is activ the adjustment was
not completed.
"nco" appears in the display !
Hz
1
Hz
0,05 ... 1
0,01
V
1
V
400
V
0 ... 1
1
0
1070066022 - 101