Technical Data
2.2
2.2
2.2
2.2
2.2
Technical Data
Technical Data
Technical Data
Technical Data
Technical Data
2.2.1 Summary Technical Data 230/ 400 V- class, Control Circuit F
2.2.1 Summary Technical Data 230/ 400 V- class, Control Circuit F
2.2.1 Summary Technical Data 230/ 400 V- class, Control Circuit F
2.2.1 Summary Technical Data 230/ 400 V- class, Control Circuit F
2.2.1 Summary Technical Data 230/ 400 V- class, Control Circuit F
fre que ncy inv e rte r, type ASC
housing siz e
mains
GB
nom . c urrent I
m ax. c urrent I m ax ( 30 s ec . )
nom . output pow er
m ax. m otor rating
recom m anded m otor rating
m ax. line cros s s ection
m ax. c able lenghts , s hielded
output voltage
s peed res olution m otor
nom . m otor voltage
nom . input c urrent
m ax. s upply c ros s s ec tion
m ax. perm is sible fus e (inert)
nom . voltage + /- 0%
m ains frequenc y
s w itc hing input side
HF- filter part no.:
nom . pow er los s
typ. braking res is tor
m in. braking resis tor
m ax. braking c urrent
operating tem perature
s torage tem perature
relative hum idity
m odel/ protective sys tem
in ac c ordanc e w ith ..
s tandards for nois e im m unity
s tandards for em itted interferenc e
s w itc hing frequenc y
part no.:
1)
Pre- assembled motor- and feedback cable are available on request.
2)
Nominal mains voltages are: 200/ 208/220/230/ 240 V .
3)
At mains voltage > 460 V AC multiply the nom. current with factor 0,86.
The technical data is for 2/4 pole standard motors. With other pole numbers the inverter must be
dimensioned onto the motor rated current. Contact BOSCH for special or medium frequency motors and
applications with longer motor cables.
Site altitude max. 2000 m. With site altitudes over 1000 m a power reduction of 1% per 100 m
must be taken into consideration.
GB - 14
1/3 - phase
[A]
[A]
[kVA]
[kW ]
[kW ]
[m m ²]
1 )
[m ]
[V]
-1
[m in
]
[V]
[A]
[m m ²]
[A]
[V]
180 ... 264
[Hz ]
1070918...
279/ 200
[W ]
[O hm ]
[O hm ]
[A]
[kHz ]
1070918...
75
220
D
D
4
5,8
7,2
10,4
1,6
4
0,75
2,2
0,75
1,5
2,5
1,5
30
50
3 x 0 ... U m ains
0,5
2 )
380/400/415/460/480
230
8
6,4
2,5
1,5
20
10
50/ 60
m ax. 1 x per m inute
200
65
100
100
270
56
160
7
5
-10...45 °C
-25...70 °C
m ax. 95% w ithout condens ation
IP20
EN 50081-1 / 50082-2
IEC 1000 4-2 /-3 /-4 /-5 /-6
EN 55011 c las s B / EN 55022 c las s A
8
8
287
288
400
550
750
E
E
E
3 - phase
9,5
12
16,5
17,1
21,6
29,7
6,6
8,3
11
4
5,5
7,5
3
4
5,5
2,5
2,5
4
50
50
50
10,5
13,2
18,1
2,5
2,5
4
20
20
25
3 )
300 ... 500
+ /- 2
278
278
278
140
200
240
150
100
82
50
50
50
15
15
15
8
8
8
289
290
291
1070066022 - 101

Werbung

Kapitel

Inhaltsverzeichnis
loading