Prolonged
operation of the
compressor
Compressor is
noisy (knocking,
metal noises)
Condensed liquid
does not drain from
the air tank

18. LONG-TERM SHUTDOWN

When there is a predisposition that the compressor shall not be used for a prolonged time period,
release air pressure in the pressure tank. Switch off the compressor by switch (5) (Fig. 2) and
disconnect the device from the mains.

19. DISPOSAL OF DEVICE

 Disconnect the device from the mains.
 Release air pressure in the pressure tank by opening the drain valve.
 Dispose of the device following all applicable environmental regulations.
 Entrust a specialised company to sort and dispose of waste.
 Worn out components have no negative environmental impact.
To protect the connected equipment from any damage, it is necessary to check
humidity of the released air from the air tank (see Chapter Technical data)

20. REPAIR SERVICE

Guarantee and post-guarantee repairs are provided by the manufacturer or organizations and
technicians approved by the manufacturer.
Warning.
The manufacturer reserves the right to make changes on the device, which will not significantly
affect properties of the device.
NP-DK50 2V MOBILE mini-1_11-2019
Low capacity of the pump
Pump failure
Air leakage in pneumatic system
Worn piston ring
Dirty inlet filter
Incorrect function of solenoid valve
Damaged piston bearing, piston
rods, motor bearing
Loose (cracked) dampening
element (spring)
Plugged filter
Solenoid valve not working
Non-functioning electronics on the
automatic condensate drain
Clean / replace the pump
Clean / replace the pump
Check pneumatic system – seal
loose connection
Replace worn piston ring
Replace dirty filter with new filter
Repair or replace fan or coil
Replace damaged bearing
Replace damaged spring
Replace filter
Replace coil
Replace valve
Replace automatic condensate
drain
28
TROUBLESHOOTING
10/2019