Comissioning and operation
17. Set millimetres using the scrollbar.
18. Press the
ð Setting are saved, and pump switches back to operating mode selection screen.
19. Go to the main menu by pressing the button
5.2.4
Starting and stopping the metering pump
5.2.4.1 Starting and stopping the EcoPro metering pump
Starting and stopping the pump conforms to manual pump operation.
1.
To start the metering pump, press the "Test" button on the pump control panel.
2.
To stop the metering pump, release the "Test" button.
5.2.4.2 Starting and stopping the EcoAdd metering pump
1.
To start the metering pump, press the 'Start button'
ð The 'operating screen' remains unchanged and the pump goes into "Stand-by".
2.
To stop the metering pump, press the 'Pause button'
5.2.5
Putting the metering station into operation
It is only permitted to operate the metering station when all operating conditions have
been met and all operating parameters comply with the technical specifications.
To put the metering station into operation, proceed as follows:
1.
Start the pump and let it run until the system circuit is filled with medium (approx. 20
minutes).
2.
Select the necessary processes on your control.
The functional principle of the standard Eco metering station then applies.
5.2.6
Monitoring the operation of the metering station
To minimise operational interruptions and safety risks, the metering station offers multiple
safety components and safety functions.
These components and functions help you to monitor machine operation as follows:
n
Fill level monitoring with suction lance
n
Fill level monitoring with automatic tank changeover
n
Self-monitoring of the EcoPro/EcoAdd metering pump
n
Pressure monitoring with multi-function valve
Metering volume monitoring with OGM
n
n
Metering volume monitoring with SMx
n
Leak monitoring with Maximat leak sensor
417101656 Rev. 01-10.2019
button.