CAUTION
The use of accessories, transducers, and cables, other than those specified or provided by the manufacturer, could
result in increased electromagnetic emissions or decreased electromagnetic immunity and result in improper
operation.
The emissions characteristics of this equipment make it suitable for use in industrial areas and hospitals (CISPR 11
class A). If it is used in a residential environment, for which CISPR 11 class B is normally required, this equipment
might not offer adequate protection to radio frequency communication services. The user might need to take
mitigation measures, such as relocating or reorienting the equipment.
Guidance and manufacturer's declaration - electromagnetic emissions
The Optional Electric Lift or Electric Litter and Optional Scale System is intended for use in an electromagnetic
environment specified below. The operator of the Optional Electric Lift or Electric Litter and Optional Scale System
should make sure that it is used in such an environment.
Emissions test
RF Emissions
CISPR 11
RF Emissions
CISPR 11
Harmonic Emissions
IEC 61000-3-2 *
Voltage Fluctuations
Flicker Emissions
IEC 61000-3-3 *
* Applies to optional electric lift or electric litter only
CAUTION
Portable RF communications equipment, including peripherals such as antenna cables and external antennas,
should be used no closer than 12 inches (30 cm) to any part of the Prime stretcher, including cables specified by
the manufacturer.
Avoid stacking or placing equipment adjacent with other equipment to prevent improper operation of the products. If
such use is necessary, carefully observe stacked or adjacent equipment to make sure that they are operating
properly.
Recommended separation distances between portable and mobile RF communications equipment and the
Optional Electric Litter and Optional Scale System.
The Optional Electric Lift or Electric Litter and Optional Scale System is intended for use in an electromagnetic
environment in which radiated RF disturbances are controlled. The customer or the user of the Optional Electric Lift
or Electric Litter and Optional Scale System can help prevent electromagnetic interferences by maintaining a
minimum distance between portable and mobile RF communications equipment (transmitters) and the Optional
Electric Lift or Electric Litter and Optional Scale System as recommended below, according to the maximum output
power of the communications equipment.
www.stryker.com

EMC information

Compliance
The Optional Electric Lift or Electric Litter and
Optional Scale System uses RF energy only for its
Group 1
internal function. Therefore, its RF emissions are
very low and are not likely to cause any
interference in nearby electronic equipment.
Class A
The Optional Electric Lift or Electric Litter and
Optional Scale System is suitable for use in all
establishments other than domestic and those
Class A
directly connected to the public low voltage power
supply network that supplies buildings used for
Complies
domestic purposes.