6 - Tighten the cable gland (F).
7 - Replace the guard (E).
The constructor has tested the appliance with its
IT
own mains gas, identified by the sticker applied to
the nameplate.
If the type of gas to be connected is different from
GB
that used for testing, proceed as follows.
1 - Turn off the gas supply tap (A).
DE
2 - Change the burner nozzle (see page 31)
3 - Adjust the gas solenoid valve (see page 29)
FR
ES
4 - Remove the sticker from the nameplate and ap-
ply the new one to identify the gas being used.
Important
On completion of the operation, make sure
that there are no gas leaks or malfunctions.
English
B
CONVERSION OF GAS SUPPLY
8 - Replace the control panel (C) on completion of
the operation.
E
D
C
- 28 -
A
G
F
A
IDM-39619401900.tif
IDM-39619402000.tif
IDM-3960200250.tif