Herunterladen Inhalt Inhalt Diese Seite drucken

Positioning The Unit - Convotherm mini OES 6.06 Installationshandbuch

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 1
2. Unit Connection

2.1 Positioning the unit

Transport unit in an upright position!
Unit dimensions and weight:
Unit + packaging:
Unit without
packaging:
Weight without
packaging
The installation surface must be
smooth, level, non-flammable and be
able to support 100 kg.
Install the combi steamer level and tilt
and slip resistant. Please use the
shims supplied to adjust the combi
steamer.
!
Install the unit at a maximum distance
of 1.15 m from the floor on a base
frame or a table, so that the operator
can see into the topmost container
(corresponds to eye height for a person
of 1.60 m).
Observe the minimum distances to
neighbouring units and non flammable
walls.
left/right/rear:
above:
heat sources:
580 x 730 x 800
515 x 599 x 627
45 kg (99.2 lbs)
50 mm
500 mm
500 mm
24
50 mm
Do not install combi steamers close to
deep fat fryers or fat cooking units.
There is a serious risk of burns for the
operator, if water splashes into hot fat.
500 mm
EN
50 mm
50 mm

Quicklinks ausblenden:

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis